Musculoskeletal Ultrasound in Orthopedics
Darryl Eugene Barnes*
Mayo Clinic Health System, Department of Orthopedics, Austin, Minnesota, USA
*Corresponding Author: Darryl Eugene Barnes, Mayo Clinic Health System, Department of Orthopedics, Austin, Minnesota, USA.
Received: October 06, 2015; Published: October 08, 2015
Citation: Darryl Eugene Barnes. “Musculoskeletal Ultrasound in Orthopedics”. EC Orthopaedics 2.4 (2015): 117-126.
Abstract
Context: Musculoskeletal ultrasound (MSUS) utilization has increased significantly over the last decade with the largest growth observed in non-radiologist. The advancement of ultrasound technology has created a safe, effective, and affordable tool that provides theorthopedic physician the ability to imagemusculoskeletal structures in real-time, assisting in the diagnosis and treatment of diseases. It is postulated that the use of MSUS is an accurate diagnostic tool and delivers accurate interventional therapies. However, the clinical outcomes of these therapies are not clear.
Evidence acquisition: Medline and PubMed where utilized to find articles published in English from 1980 to 2015. Additional articles were acquired from reference lists of research articles.Textbooks were utilized asbasic science principle reference.
Results: The body of data reviewed supports the postulate that MSUS is and accurate diagnostic tool that also delivers guided therapies effectively. However, there are data that suggest that there is no significant difference in clinical outcomes between injecting corticosteroids with or without the use of MSUS. More study is needed to make definitive conclusions about the outcomes ofother specific therapies utilizing MSUS.
Conclusions: MSUS is an accurate diagnostic and interventional treatment tool, but may not provide superior clinical outcomes compared to palpation-guided injections of corticosteroids in many cases. However, more study is needed before a definitive conclusion can be drawn concerning the clinical outcomes of other specific treatments utilizing MSUS.
Strength-of-Recommendation Taxonomy (SORT):
a. Diagnostic and interventional accuracy of MSUS = A,
b. Treatment outcome of MSUS interventional therapies = B
Keywords:Ultrasound; Sonography; Musculoskeletal; Physics; Accuracy
Introduction
Musculoskeletal ultrasound (MSUS) is becoming a ubiquitous tool in a growing number of orthopedic physician’s hands. The appreciation of ultrasound imaging of musculoskeletal structures has gained much popularity recently in the United States and has been recognized as a tool that offers a great amount of accurate diagnostic information. In addition, it has been found to improve accuracy of certain interventional techniques, thus enhancing patient care. Much technological advancement has been made since Pierre Curie’s discovery of the piezoelectric effect in 1880. Improvements in image quality have been paramount in the development of MSUS, allowing the practitioner to image tissues dynamically and in greater detail than ever before. In many cases producing higher resolution images than comparative magnetic resonance imaging (MRI).[21] The creation of the linear array transducer helped reduce tendon and ligament artifact when compared to the original curvilinear transducer configuration. Additionally, conversion from analog to digital signal processing has allowed new capabilities that improve resolution and enhancement to image quality such as displaying multiple focal zones, video capturing, compound, panoramic and harmonic imaging.[47] With these technical advancements and the increased affordability of ultrasound equipment many providers are integrating this tool into their practices today. [59] Organizations such as American Institute of Ultrasound in Medicine (AIUM) and the American Registry for Diagnostic Medical Sonography (ARDMS) have recognized this trend early and have supported practitioners by providing general guidance, educational resources, accreditation for practices, and credentialing for providers.
Ultrasound Basics
Understanding the basic physical characteristics of acoustic energy and how it is transferred through tissues is paramount to producing a high quality ultrasound image and avoiding the pitfalls generated by sonographic artifacts. Acoustic energy is a physically observable event produced by a vibrating mass that transfers its energy from one point in space to another. The frequency of the ultrasound beam used in medical ultrasound image generation is between 1 and 30 MHz and for reference human hearing is in the range of 20 Hz to 20 KHz. [43]
Image Generation
An ultrasound image is generated by a computer processor housed in the ultrasound machine that generates alternating electrical pulses and transmits them through wires to an array of crystals in the transducer (or probe). Here the electrical energy is converted to acoustic energy (ultrasound) by the crystal elements that vibrate at certain frequencies a process termed the piezoelectric effect. This acoustic energy is then transmitted through a medium (aqueous gel) into the body of tissue. Some of the ultrasound beam will be reflected back by the tissues to the piezoelectric crystals in the transducer and the acoustic energy will then convert into electrical energy, by the reverse piezoelectric effect, which is then transmitted back to the computer’s processor where it will generate an image on a video display. [38,43]
Image Optimization
When ultrasound is transmitted through tissue it will encounter an acoustic interface and some of the sound will be reflected back toward the transducer forming echoes that are useful in producing a clear image of the tissue. However, most of the acoustic energy will be absorbed or refracted by the tissue and will not contribute to the image. [38] Furthermore, a portion of the ultrasound beam may contribute to image artifacts (discussed later in this paper) and typically are undesirable because it may degrade the image quality.
The depth of ultrasound beam is inversely related to the frequency of the ultrasound beam.[43] High frequency beams create high-resolution images of superficial structures (e.g. tendons crossing at the wrist), but provide very poor images of deep structures (e.g. hip joint) secondary to sound attenuation properties of tissue. Low frequency beams provide better ability for sound to penetrate to deeper tissue structures creating echoes on the image display. [43]
The computer processor determines the position of each point where sound is reflected in the tissue and displays it accurately in the image by determining what point on the horizontal plane of the crystal array a reflected sound strikes and using the velocity equation (v = d/t, where average v in human tissue is 1540 m/s) to determine its depth. The echoes are also displayed on a grey-scale spectrum of brightness that is directly proportional to the intensity or amplitude of the echo. [43] This type of scanning is referred to as B-mode or “brightness modulation”. As stated before, much of the sound generated by the transducer is lost in the tissue and does not help form the image. To remedy this an amplifier in the computer can increase the electrical pulse returned from the transducer producing a brighter signal of the entire image, termed overall gain, a function found on all modern ultrasound machines. Furthermore, this can also be completed based on the velocity equation to amplify signals coming from certain depths, termed time gain compensation (TGC) or depth gain compensation (DGC). [38,43]
An additional intricacy of the computer’s processor and the transducer’s array of multiple piezoelectric crystals allows for the ability to focus the ultrasound beam at multiple levels in the tissue improving spatial resolution of the image, termed electronic focusing. [43] Spatial resolution is composed of lateral and axial resolution and is inversely related to the wavelength (l) and directly related to frequency (f) (i.e. l = c/f; c = velocity of sound in human tissue = 1540 m/s). Lateral resolution is the ability to perceive two or more objects side-by-side and axial resolution is the ability to perceive two or more structures that are separated in the axis of the beam. [21,43] However, the complexity and time needed to form each focal zone will increase the data load to the processor and thus as one increases the number of focal zones the frame rate decreases, reducing temporal resolution, loosing the ability to produce a real-time image. [38]
The amount of sound reflected by the body is directly proportional to the tissues density and the angle of the ultrasound beam in relationship to a particular mass construct, such as a tendon. [1] For example, if denser tissue (e.g. tendon) is adjacent to less dense tissue (e.g. muscle), more sound is reflected back to the transducer from the tendon and it appears brighter than muscle on the image-viewing screen. In addition, if the ultrasound beam is directed in a perpendicular plane to the tendon (90 degrees) more sound is reflected from it and it will appear brighter, improving the generated ultrasound image. This type of image optimization technique requires the sonographer to dynamically manipulate the transducer to optimally align the angle of incidence. The angle of incidence is the measure angle between the vector of the emitted ultrasound beam and the perpendicularline from the reflective surface of the specific tissue being interrogated. This angle should be close to zero, angles over 5-10 degrees typically will produce less echoes on the display. [2,6]
Blood flow in large vessels can be indentified and quantified readily by the use of the ultrasound machines color Doppler function. Smaller vessels can be indentified with a more sensitive option termed power Doppler ultrasound (PDU). Both of these methods use data in each frame of an image looking for a Doppler shift in each ultrasound beam sent to detect movement caused by blood flow. [43,47] The color Doppler function has the ability to detect average speed and direction of blood flow, whereas PDU demonstrates the size of the reflections from blood flow. [47,50]
Image Artifacts
It is important for the sonographer to understand how sonographic artifacts (aberrancies in ultrasound images) are generated and how they can lead to misdiagnosis. On the other hand, understanding the nature of these artifacts can be beneficial to the astute scanner. The following are descriptions of common sonographic artifacts encountered when performing MSUS and common techniques to either avoid these scanning pitfalls or making the artifact useful by exploiting it.
Anisotropyis a hypoechoic area within a fibrillar structure such as a tendon or ligament that is caused by reflection of sound away from the transducer due to the increased angle of incidence. This typically occurs when scanning curved surfaces such as the distal portion of the supraspinatus tendon. If the angle of incidence is greater than 5-10 degrees the normal echo intensity is lost producing a hypoechoic area within the structure (i.e. tendon or ligament) that may be misinterpreted as a tendon or ligament tear.2, 6In some instances this can be used to the sonographer’s advantage. For instance, in the foot, the plantar heel consists of hyperechoic skin, fat pad, plantar fascia (that has a similar echotexture to ligament) and bone. Often it is difficult to discriminate the differences between the fat and plantar fascia. But by employing the principles of anisotropy one can make the plantar fascia more conspicuous by increasing the angle of incidence in reference to the plantar fascia thereby making it appear hypoechoic compared to the fat pad. Fat does not create anisotropy artifact and thus its echo appears similar at varying angles of the transducer in relation to the structure being scanned. This technique can be used in other anatomical locations that have fatty structure adjacent to tendons and ligament, such as the wrist and ankle. [6, 45]
Shadowing is an artifact phenomenon caused by one or a combination of ultrasound beam being absorbed by the tissue, reflected away from the transducer or refraction through the tissue, resulting in an anechoic region deep to the acoustic interface in the image viewing field. [43] This artifact phenomenon has also been termed to by some as “posterior” acoustic shadowing, because it appears behind or deep to the structure in question. [3, 22] These acoustic interfaces that display shadowing are dense structures such as bone or calcific deposits that reflect nearly all of the sound back strictly limiting the sound penetration to areas deeper than the bone or calcification, thus producing no echoes beyond its interface creating the anechoic region deep to it. In some instances this phenomenon can be useful to the sonographer when diagnosing tears in tendons because the torn edges refract the ultrasound away from the transducer producing an anechoic region deep to the pathologic region. [27]
Posterior acoustic enhancement (or increased through-transmission) is an artifact that occurs when the ultrasound beam passes through with less attenuation than surrounding tissue, reflecting more intense echoes deep to the fluid structure (e.g. cyst).
Posterior reverberationartifact is a series of similar appearing echoes deep to a multilayer dense and flat surface (i.e. metal needle).This occurs when acoustic energy is transmitted back and forth between the surfaces of the object. Repetitive images appear deeper to the objects true reflection point secondary to the time delay in the reverberation echoes reaching the transducer. [43] Metal objects tend to produce uniform reverberation echoes and is further termed ring-down artifact. [43] Gas bubbles in soft tissue produce reverberation echoes as well, but these echoes appear to narrow farther away from the transducer, termed comet-tail artifact. [43]
Diagnostic and Interventional Imaging
MSUS utilization has increased significantly over the last 10 years among all user groups. Interestingly, non-radiologists have seen the largest growth in the use of this technology in their private offices over this time period. [59] Overall this development is linked to the decrease in cost of ultrasound machines and the widening scope of indication for use, opening the door to orthopedic physicians. [32,59] It is expected that this group will continue to adopt musculoskeletal ultrasound into their practices and appears to be directly related to the decreasing cost, technological improvements, patient satisfaction and the development of formal training and testing.
The AIUM in conjunction with the American College of Radiology (ACR), the Society for Pediatric Radiology (SPR), and the Society of Radiologist in Ultrasound (SRU) has developed practice guidelines specifically outlining the performance and recording of the musculoskeletal ultrasound examination. [3] These guidelines specifically review the indications and specifications for anatomical region examinations and requirements for interventional methods, among other important attributes that will not be duplicated in this review paper. However, the accuracies of diagnostic and effectiveness of interventional methods of musculoskeletal ultrasound in a broad representation of anatomical sites are reviewed here.
Normal Versus Abnormal Appearances of Common Musculoskeletal Structures
With a clear understanding of the basic principles of ultrasound physics as described earlier in this paper, one will better understand the images generated when scanning normal and abnormal tissues.
Recognizing a tissues specific ability to produce an echo will allow the observer to differentiate musculoskeletal structures such as vessels, nerves, muscle, tendons, ligaments, fascia and bone. In addition, it is of significant importance that the scanner have an in depth knowledge of musculoskeletal anatomy of the specific region being scanned.
The echoes produced by specific structures can be characterized in terms of their echogenicity (i.e. ability to reflect sound: hyperechoic, hypoechoic, anechoic, isoechoic), echotexture (i.e. pattern of reflected sound: fibrillar, fascicular, pinnate, honeycomb, broom end, starry night), ability to produce anisotropy, ability to be compressed with transducer pressure and blood flow. [2,63] The following are specific ultrasonographic characteristics of normal and abnormal musculoskeletal structures that can be accurately visualized with ultrasound:
Vessels (veins and arteries) in the normal state appear tubular and anechoic or hypoechoic. They demonstrate flow on Doppler scanning and are compressible (compressibility: vein > arteries). In the abnormal state there may be a hypoechoic mass within the thickened vessel wall and reduced or absence blood flow on Doppler examination representing a vessel thrombosis. [11,33,49] Additionally, there may be an enlarged region of the vessel that would be consistent with an aneurysm or pseudo aneurysm. [46,51,61] PDU is particularly helpful in MSUS imaging when one is attempting to detect small amounts of blood flow within small vessels scanned in tendinopathic tissue. [60] The prognostic value of PDU has been studied in many tendinopathic conditions. It is thought that the presence of neovascularization in the tendon may be associated with poorer outcomes. One such study looked for presence of neovascularization in the mid-portion of the Achilles tendon of 634 asymptomatic runners and found the likelihood of developing symptomatic disease within 1 year in those with neovascularization was 6.9 fold (P=0.0001). [29]
Furthermore, an earlier study showed that there was no significant correlation between the presence or absence of neovascularization and pain/dysfunction at baseline testing of symptomatic patients. But after 12 weeks of physical therapy this correlation was present. Moreover, there was no correlation in the presence or absence of neovascularization at baseline and treatment outcome. [15] This would support earlier studies that suggested that there is no prognostic value for clinical outcome using PDU in symptomatic patients with Achilles tendinopathy. [74] However, another investigation looking at chronic tennis elbow patients, interrogating the common extensor tendon origin at the lateral epicondyle with PDU and comparing it to grey-scale findings found that a positive PDU finding in the tendon alone had a positive likelihood ratio of 45.39 of accurately diagnosing tennis elbow. [67]  Furthermore, they found a negative likelihood ratio of 0.05 of diagnosis in those with negative PDU and grey-scale findings. Positive grey-scale findings alone are not as diagnostically accurate as PDU findings. [67]  However, other study of tennis elbow demonstrates that the positive findings on PDU do not coordinate well with change in severity of pain and dysfunction, and therefore may not be good predictor of clinical outcomes as seen in the aforementioned Achilles tendon studies. [9] Additionally, when looking at the neovascularization in the patellar tendon associated with jumper’s knee and potential treatments early study showed that interrupting the new vessels with injection of a sclerotic agent, polidocanol, may be an effective solution for patients. [25,30] However, long-term study of outcomes showed only moderate improvement at 24 months post treatment with polidocanol injection and that other invasive treatment such as arthroscopic shaving of the tendinopathic area may be superior. [31,73] These observations would suggest that presence of neovascularization on PDU in tendons is helpful in making an accurate diagnosis but may not be a good predictor of treatments outcomes.
Nerves have mixed echogenicity (hyperechoic/hypoechoic) based on the differences in echo generation by the nerve fascicles high fluid content (hypoechoic) versus the denser epineurium (hyperechoic). This generates two types of echotexture depending on the plane in which the nerve is scanned. Along the longitudinal axis it has a fascicular pattern and in the transverse axis it appears to have a “honeycomb” pattern. In addition, nerves display much less anisotropy than tendon requiring less attention to the angle of insonation by the sonographer. [45] Large peripheral nerves such as the median and ulnar nerves can easily be traced in the transverse plane with good differentiation from adjacent tendons. [45] This technique can be used with the addition of physical examination techniques to elicit signs and symptoms such as Tinel’s sign or limb manipulation to elicit nerve subluxation and dislocation (e.g., ulnar nerve subluxation from the cubical tunnel). With nerve entrapment syndromes (e.g. Carpal Tunnel Syndrome) the nerve will appear hypoechoic and swollen proximally to the compression. [45,70] Meta-analysis has shown that the cross-sectional area of the median nerve at the carpal tunnel inlet equal to or greater than 9mm2 is the single best diagnostic decisive factor, having a diagnostic odds ratio of 40.4, a sensitivity of 87.3% and a specificity of 83.3%. [66] However, other studies have demonstrated that US is not as accurate as electro-diagnostic testing, which remains the gold standard. [16,17,56] Moreover, new advancements in insonation technology are allowing even smaller peripheral nerves, such as those in the hand and wrist area, to be interrogated with good accuracy in diagnosing peripheral neuropathies. [65,70] Furthermore, ultrasound guided injection into or around peripheral nerves for treating conditions such as inter digital neuroma and providing nerve blocks is very accurate. [2,20]
Musclehas mixed echogenicity (hypoechoic muscle fascicles > hyperechoic perimysium and epimysium). In the longitudinal axis it has a “pinnate” or feather-like echotexture and in the transverse axis, a “starry night” echotexture. [63,70] In the injured state the normal patterns are disrupted. In mild grade injuries there may be regions of slight hypoechogenicity and loss of the normal pinnate echotexture. In higher grade injuries there may be larger regions of more conspicuous hypoechogenicity or anechoic areas consistent with hematoma formation. In more advance injury there may be complete disruption of the muscle fiber with intervening hematoma of which typically will occur at the myotendinous junction. [10,70]
Tendons appear hyperechoic and have a fibrillar echotexture in the longitudinal axis and have a broom-end appearance on the transverse axis image. Tendon tissue is comprised of densely packed linear collagen bundles that are not compressible and reflect sound uniformly creating susceptibility to anisotropy. [1,6,45] An acutely injured tendon may result in a partial or full thickness tear. Here the scanner would see possible thinning of the tendon and/or disruption of the fibrillar structure and an intervening hypoechoic or anechoic region representing the tear, which can be confirmed in two orthogonal planes.[1,6,45,62] Furthermore, dynamic study may reveal gapping of the tendon parts in high-grade partial tears and full thickness tears. In addition, shadowing artifact may occur deep to the tear secondary to refraction of the torn edges of the tendon. [27] In chronic conditions of the tendon or tendinosis, the affected area of the tendon appears hypoechoic and enlarged and may be hyperemic as detected by PDU examination. [1,45,60] Tenosynovitis can be simple or complex in nature. Simple tenosyonvitis has the appearance of an anechoic region (simple fluid) surrounding a tendon. Whereas, in cases of complex tenosyonvitis, a mixed echogenic fluid mass is seen surrounding the tendon. A thickened synovial membrane may also accompany it with the presence of hyperemia detected by PDU examination.[1,45] It is important to keep in mind that ultrasound cannot rule out infectious conditions and one must use good clinical judgment and consider aspiration of the complex fluid for culturing to rule out infectious synovitis. [63]
Ultrasound diagnostic accuracy of tendon pathology has been extensively investigated. In the Achilles tendon the differential diagnostic accuracy, comparing ultrasound to surgical findings, of full versus partial thickness tears or tendinosis is 92%, with a 100% sensitivity and specificity of 83%. [27] When comparing accuracy of magnetic resonance imaging (MRI) to ultrasound diagnosis of the patellar tendinopathy, ultrasound was found to be more accurate than MRI. [72] Whereas when considering the diagnostic accuracy of sonographic measurements of the common extensor tendon (CET) in tennis elbow, early study show that increases in CET cross-sectional area equal to or greater than 32 mm2 (accuracy 84.2%; sensitivity 86.3%; specificity 82.5%) and thickness of 4.2 mm (accuracy 87.7%; sensitivity 78.4%; specificity 95.2%) correlated with the presence of tendinosis, but further study is needed to determine the utility of these measurement and correlation to severity of symptoms. [40] Furthermore, the accuracy of detecting full-thickness tears of the long head of biceps tendon is 97% (sensitivity 88%; specificity 98%), whereas it was only found to have an88% accuracy rate for partial tears. [61] Finally, the diagnosis of rotator cuff pathology has been the focus of many studies. Particularly comparing the accuracy of MRI versus MSUS in detecting rotator cuff tears. One meta-analysis evaluating 65 articles focusing on accuracy of MRI, magnetic resonance arthrography (MRA), and MSUS found that MRA is the most sensitive and specific imaging modality for full and partial-thickness rotator cuff tears. But also elicited that MSUS and MRI have comparable sensitivity and specificity. [14] Another meta-analysis evaluating 62 studies focusing on accuracy of MSUS and either arthroscopic or open surgical findings, in regards to rotator cuff tears, found MSUS to be accurate in diagnosing partial thickness tears (sensitivity 84%; specificity 89%) and full-thickness tears (sensitivity 96%; specificity 93%). [64]
Ligament in its normal state appears similar to tendon and can be differentiated simply by scanning end-to-end over the structure and observing the attachments. However, the collagen fibers of the ligament are not as uniform as tendon making it slightly less vulnerable to anisotropy. In the low-grade injured state this fibrillar structure may be thickened and hypoechoic. Moreover, in the high-grade injury state the ligament may have a partial or full-thickness tear represent sonographically by disruption of the fibrillar structure that may be made more conspicuous by stress testing. [37]
Bone is very dense and is an excellent reflector of acoustic energy and therefore is hyperechoic. As stated earlier ultrasound cannot visualize structures deep to bone or highly calcified structures. Therefore ultrasound is limited only to evaluation of the boney surface. When performing an ultrasound scan it is very common to use bone as an anatomical landmark or reference point to other anatomical structures such as the lateral epicondyle and its relationship to the common extensor tendon. Moreover, multiple studies have shown that ultrasound is a good imaging modality for fracture detection in non-intra-articular long bones, nasal bones, ribs, sternum, and phalanges. [4,19,26,34,71] One recent prospective study assessing 86 patients presenting to an ER with clinically suspected fractures were evaluated with X-ray and ultrasound. They showed that US had a sensitivity of 94% and a specificity of 92% when looking at long bones fractures. [4]
Accuracy of Ultrasound Guided Injections
Historically, injections into musculoskeletal soft tissues (e.g., joints, peri-tendinous, muscle and peri-neural regions) have been performed by palpation-guided injection (PGI). PGI uses the finger tip(s) to palpate anatomical landmarksin attempts to accurately place the needle tip into the intended target. MSUS allows the sonographer to visualize the needle tip within the body, in many cases, and has great potential of accurately guiding a needle to target tissue. Over the last 10 years the use of MSUS to guide procedures, especially injections, have significantly increased among non-radiologist as described earlier in this paper. This may be particularly beneficial for patients with difficult anatomy, deep non-palpable target areas, or those on anticoagulants. However, one controlled laboratory study concluded that the accuracy rate for ultrasound guided placement of a compartment pressure needle into the deep posterior compartment of the leg was 88% compared to the 90% accuracy rate of palpation-guided placement. [53] Nevertheless,it is thought that USGI is more accurate than PGI. Choudur., et al. demonstrated a 99% accuracy rate of injection of contrast into the wrist, shoulder, knee, and hip joints. [8] In review of multiple studies evaluating USGI in patients and cadaveric specimens of multiple anatomical regions in the upper and lower extremities demonstrate high accuracies rates that are superior to PGI. [8, 13, 23, 24, 28, 36, 42, 48, 52, 54, 55] However, not all studies revealed superior USGI accuracy rates in all target areas. Khosla., et al. reported equally superior accuracy rates for USGI and PGI in the tibiotalar and subtalar joints. [36] Rutten., et al. also demonstrated equally high accuracy rates for USGI and PGI in the subacromial-subdeltoid bursa. [57]
Even though the accuracy of placement of injectate utilizing USGI appears to be better than PGI in most studies, the superior efficacy measured by clinical outcomes has not been demonstrated with much vigor in the current body of literature. Cunnington., et al. showed in a double-blind, controlled investigation that there was no significant difference between clinical outcomes of patient receiving USGI and PGI of corticosteroid for inflammatory arthritis in the wrist, elbow, shoulder, ankle, or knee joints. [12] Dogu., et al. demonstrated no difference in either accuracy rate of USGI versus PGI or difference in clinical outcome of the delivery of cortisone by either method into the subacromial region for subacromial impingement syndrome. [18] In addition, Bloom., et al. concluded in their 2012 Cochrane review that the literature up to June 2011 does not support any advantage of USGI of cortisone into the shoulder for common pathologies. [5]
Conclusion
As orthopedic physicians actively adopt MSUS into clinical practice it is paramount to understand how acoustic energy interacts with human tissue in order to create high-quality images. This complex technology, which has been refined and simplified over many years, in its current form has proven to be an accurate tool for diagnostic and interventional imaging of musculoskeletal tissues. However, more study is needed to definitively demonstrate the efficacy of such specific interventions on clinical outcomes.
Bibliography
  1. Adler RS and Finzel K. “The complementary roles of MR imaging and ultrasound of tendons”. Radiologic Clinics of North America43.4 (2005): 771-807.
  2. Adler RS and Sofka CM. “Percutaneous ultrasound-guided injections in the musculoskeletal system”. Ultrasound Quarterly19.1 (2003): 3-12.
  3. American Institute of Ultrasound in Medicine. “AIUM practice guideline for the performance of a musculoskeletal ultrasound examination”. Journal of Ultrasound in Medicine31.9 (2012): 1473-1488.
  4. Beltrame V., et al. “Sonographic evaluation of bone fractures: a reliable alternative in clinical practice”. Clinical Imaging36.3 (2012): 203-208.
  5. Bloom JE., et al. “Image-guided versus blind glucocorticoid injection for shoulder pain (review)”. The Cochrane Library8 (2012): 1-50.
  6. Rasmussen OS. “Sonography of tendons”. Scandinavian Journal of Medicine & Science in Sports 10.6 (2000):360-364.
  7. Buck F., et al. “Ultrasonographic evaluation of degenerative changes in the distal radioulnar joint: Correlation of findings with gross anatomy and MR arthrography in cadavers”. European Journal of Radiology77.2 (2011): 215-221.
  8. Choudur HN and Ellins ML. “Ultrasound-guided gadolinium joint injections for magnetic resonance arthrography”. Journal of Clinical Ultrasound 39.1 (2010): 6-11.
  9. Clarke AW., et al. “Lateral elbow tendinopathy: correlation of ultrasound findings with pain and functional disability”. The American Journal of Sports Medicine38.6 (2010): 1209-1214.
  10. Connell D., et al. “Longitudinal study comparing sonographic and MRI assessments of acute and healing hamstring injuries”. AJR183.4 (2004): 975-984.
  11. Cronan JJ., et al. “Deep venous thrombosis: US assessment using vein compression”. Radiology 162.1 (1987): 191-194.
  12. Cunnington J., et al. “A randomized, double-blind, controlled study of ultrasound-guided corticosteroid injection into the joint of patients with inflammatory arthritis”.Arthritis & Rheumatism 62.7 (2010): 1862-1869.
  13. Curtiss HM., et al. “Accuracy of ultrasound-guided and palpation-guided knee injections by an experienced and less-experienced injector using a superolateral approach: a cadaveric study”. Physical medicine and rehabilitation3.6 (2011): 507-515.
  14. De Jesus J., et al. “Accuracy of MRI, MR arthrography, and ultrasound in the diagnosis of rotator cuff tears: a meta-analysis”. AJR 192.6 (2009): 1701-1707.
  15. De Vos RJ., et al. “The value of power Doppler ultrasonography in Achilles tendinopathy”. The American Journal of Sports Medicine35.10 (2007): 1696-1701.
  16. Deniz FE., et al. “Comparison of the diagnostic utility of electromyography, ultrasonography, computed tomography, and magnetic resonance imaging in idiopathic carpal tunnel syndrome determined by clinical findings”.  Neurosurgery70.3 (2012): 610-616.
  17. Descatha A., et al. “Meta-analysis on the performance of sonography for the diagnosis of carpal tunnel syndrome”.  Seminars in Arthritis & Rheumatism 41.6 (2012): 914-922.
  18. Dogu B., et al. “Blind or ultrasound-guided corticosteroid injections and short-term response in subacromial impingement syndrome”.  American Journal of Physical Medicine & Rehabilitation91.8 (2012): 658-665.
  19. Drakonaki E and Garbi A. “Metatarsal stress fracture diagnosed with high-resolution sonography. Journal of Ultrasound in Medicine 29.3 (2010): 473-476.
  20. Eichenberger U., et al. “Ultrasound-guided blocks of the ilioinguial and iliohypogastric nerve: accuracy of a selective new technique confirmed by anatomical dissection”. British Journal of Anaesthesia 97.2 (2006): 238-243.
  21. Erickson SJ. “High-resolution imaging of the musculoskeletal system”. Radiology 205.3 (1997): 593-618.
  22. Fazal MA., et al. “Ultrasonography and magnetic resonance imaging in the diagnosis of Morton’s neuroma”. Journal of the American Podiatric Med Association102.3 (2012): 184-186.
  23. Finnoff JT., et al. “Accuracy of ultrasound-guided versus fluoroscopically guided contrast-controlled piriformis injections”. Journal of Ultrasound Medicine27.8 (2008): 1157-1163.
  24. Finnoff JT., et al. “Accuracy of ultrasound-guided versus unguided pes anserinus bursa injections. Physical Medicine and Rehabilitation 2.8 (2010): 732-739.
  25. Gisslen K and Alfredson H. “Neovascularisation and pain in jumper’s knee; a prospective clinical and sonographic study in elite junior volleyball players”. British Journal of Sports Medicine 39.7 (2005): 423-428.
  26. Graif M., et al. “Sonographic detection of occult bone fractures”. Pediatric Radiology 18.5 (1988): 383-385.
  27. Hartgerink P., et al. “Full- versus partial-thickness Achilles tendon tears: sonographic accuracy and characterization in 26 cases with surgical correlation”. Radiology 220.2 (2001): 406-412.
  28. Hashiuchi T., et al. “Accuracy of the biceps tendon sheath injection: ultrasound-guided or unguided injection? A randomized controlled trial”.  Journal of Shoulder Elbow Surgery20.7 (2011): 1069-1073.
  29. Hirschmuller A., et al. "Prognostic value of Achilles tendon Doppler sonography in asymptomatic runners”. Medicine & Science in Sports & Exercise 44.2 (2012): 199-205.
  30. Hoksrud A and Bahr R. “Ultrasound-guided sclerosing treatment in patients with patellar tendinopathy (jumper’s knee): 44-month follow-up”. American Journal of Sports Medicine39.7 (2011): 2377-2380.
  31. Hoksrud A., et al. “Ultrasound-guided sclerosis of neovessels in patellar tendinopathy: a prospective study of 101 patients”. American Journal f Sports Medicine 40.3 (2012): 542-547.
  32. Jacobson JA. “Musculoskeletal ultrasound: focused impact on MRI”. AJR 193.3 (2009): 619-27.
  33. Janssen MCH., et al. “Diagnosis of deep vein thrombosis, an overview”. Netherlands Journal of Medicine48 (1996): 109-121.
  34. Jenkins CN and Thuau H. “Ultrasound imaging in assessment of fractures of the orbital foor”. Clinical Radiology52.9 (1997): 708-711.
  35. Kelly AM and Fessel l D. “Ultrasound compared with magnetic resonance imaging for the diagnosis of rotator cuff tears: a critically appraised topic”. Seminars in Roentgenology 44.3 (2009): 196-200.
  36. Khosla S., et al. “Ultrasound guidance for intra-articular injections of the foot and ankle”. Foot & Ankle International30.9 (2009): 886-890.
  37. Khoury V., et al. “Musculoskeletal sonography: a dynamic tool for usual and unusual disorders”. AJR188.1 (2007): W63-W73.
  38. Kremkau FW. “Sonography principles and instruments”. 8th ed. St. Louis, Missouri: Elsevier Saunders; (2011): 292.
  39. Lecoq B., et al. “Ultrasound-guided percutaneous surgery for carpal tunnel syndrome: a cadaver study”. Joint Bone Spine 78.5 (2011): 516-518.
  40. Lee MH., et al. “Utility of sonographic measurement of the common tensor tendon in patients with lateral epicondylitis”. AJR196.6 (2010): 1363-1367.
  41. Levine BD., et al. “Imaging of the shoulder: a comparison of MRI and ultrasound”. American College of Sports Medicine11.5 (2012): 239-243.
  42. Lohman M., et al. “Ultrasound guidance for puncture and injection in radiocarpal joint”. Acta Radiologica48.7 (2007): 744-747.
  43. Lutz H and Buscarni E. “WHO manual of diagnostic ultrasound”. 2nd ed. Zabbar, Malta: Gutenberg Press Ltd. (2011): 3-26.
  44. Margetic P and Pavic R. “Comparative assessment of the acute ankle injury by ultrasound and magnetic resonance”. Collegium Antropologicum36.2 (2012): 605-610.
  45. Martinoli C., “Ultrasound of tendons and nerves”. European journal of Radiology12.1 (2002): 44-55.
  46. Maydew MS. “Dorsalis pedis aneurysm: ultrasound diagnosis”. Emergency Radiology13.5 (2007): 277-280.
  47. McNally E. “The development and clinical applications of musculoskeletal ultrasound”. Skeletal Radiology 40.9 (2011): 1223-1231.
  48. Muir JJ., et al. “The accuracy of ultrasound-guided and palpation-guided peroneal tendon sheath injections”. American Journal of Physical Medicine & Rehabilitation 90.7 (2011): 564-571.
  49. Murphy TP and Cronan JJ. “Evolution of deep venous thrombosis: a prospective evaluation with US”. Radiology 177.2 (1990): 543-548.
  50. Newman JS., et al. “Detection of soft-tissue hyperemia: value of power Doppler sonography”. AJR 163.2 (1994): 385-389.
  51. Ozdemir H., et al. “Pseudoaneurysm of the dorsalis pedis arthery: color doppler sonographic and angiographic findings”. Journal of Clinical Ultrasound31.5 (2003): 283-287.
  52. Park YB., et al. “Accuracy of blind versus ultrasound-guided suprapatellar bursal injection”. Journal of clinical Ultrasound 40.1 (2012): 20-25.
  53. Peck E., et al.” Accuracy of palpation-guided and ultrasound-guided needle tip placement into the deep and superficial posterior leg compartments”. American journal of Sports Medicine39.9 (2011): 1968-1974.
  54. Peck E., et al. “Accuracy of ultrasound-guided versus palpation-guided acromioclavicular joint injections: a cadaveric study”. PM&R2.9 (2010): 817-821.
  55. Reach JS., et al. “Accuracy of ultrasound guided injections in the foot and ankle”. Foot & Ankle International30.1 (2009): 239-242.
  56. Roll S., et al. “Screening for carpal tunnel syndrome using sonography”. Journal of Ultrasound in Medicine30.12 (2011): 1657-1667.
  57. Rutten MJ., et al. “Injection of the subacromial-subdeltoid bursa: blind or ultrasound-guided?” Acta Orthopaedica78.2 (2007): 254-257.
  58. Sabeti Aschraf M., et al. “Ultrasound guidance improves the accuracy of the acromioclavicular joint infiltration: a prospective randomized study”. Knee Surgery, Sports Traumatology, Arthroscopy19.2 (2011): 292-295.
  59. Sharpe RE., et al. “Dramatically increased musculosketal ultrasound utilization from 2000 to 2009, especially by podiatrist in private offices”. Journal of the American College of Radiology9.2 (2012): 141-146.
  60. Silvestri E., et al. “Power Doppler analysis of tendon vasculatization”. International Journal of Tissue Reactions 25.4 (2003): 149-158.
  61. Skendzel JG., et al. “Long head of biceps brachii tendon evaluation: accuracy of preoperative ultrasound”. American Journalism Review197.4 (2011): 942-948.
  62. Smith J and Finnoff JT. “Diagnostic and Interventional Musculoskeletal Ultrasound: Part 1. Fundamentals”. Physical Medicine and Rehabilitation1.1 (2009): 64-75.
  63. Smith J and Finnoff JT. “Diagnostic and Interventional Musculoskeletal Ultrasound: Part 2. Clinical Applications”. Physical Medicine and Rehabilitation1.2 (2009): 162-177.
  64. Smith TO., et al. “Diagnostic accuracy of ultrasound of rotator cuff tears in adults: a systematic review and metapanalysis”. Clinical Radiology66.11 (2011): 1036-1048.
  65. Stokvis A., et al. “High-resolution ultrasonography of the cutaneous nerve branches in the hand and wrist”. The Journal of Hand Surgery 34.6 (2009): 766-771.
  66. Tai T., et al. “Ultrasonography for diagnosing carpal tunnel syndrome: a meta-analysis of diagnostic test accuracy”. Ultrasound in Medicine & Biology38.7 (2012): 1121-1128.
  67. Toit C., et al. “Diagnostic accuracy of power Doppler ultrasound in patients with chronic tennis elbow”. Journal of Sports Medicine42.11 (2008): 872-876.
  68. Tok F., et al. “Musculoskeletal ultrasound for sports injuries”. European Journal of Physical and Rehabilitation Medicine48.4 (2012): 651-663.
  69. Valle M and Zamorani MP. “Nerve and Blood Vessels. In: Bianchi S, Martinoli C. eds. Ultrasound of the musculoskeletal system”.  (2007): 97-133.
  70. Walker FO. “Imaging nerve and muscle with ultrasound”. Supplements to Clinical Neurophysiology57 (2004): 243-254.
  71. Wang C., et al.Sonographic detection of occult fractures in the foot and ankle”. Journal of Clinical Ultrasound 27.8 (1999): 421-425.
  72. Warden SJ., et al. “Compatative accuracy of magnetic resonance imaging and ultrasonography in confirming clinically diagnosed patellar tendinopathy”. American  Journal of Sports Medicine35.3 (2007) : 427-436.
  73. Willberg L., et al. “Sclerosing polidocanol injections or arthroscopic shaving to treat patellar tendinopathy/jumper’s knee? A randomized controlled study”. British Journal of Sports Medicine45.5 (2011): 411-415.
  74. Zanetti M. et al. “Achilles tendons: clinical relevance of neovasculatization diagnosed with power Doppler US”. Radiology 227.2 (2003): 556-560.
Copyright: © 2015 Darryl Eugene Barnes. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

PubMed Indexed Article


EC Pharmacology and Toxicology
LC-UV-MS and MS/MS Characterize Glutathione Reactivity with Different Isomers (2,2' and 2,4' vs. 4,4') of Methylene Diphenyl-Diisocyanate.

PMID: 31143884 [PubMed]

PMCID: PMC6536005


EC Pharmacology and Toxicology
Alzheimer's Pathogenesis, Metal-Mediated Redox Stress, and Potential Nanotheranostics.

PMID: 31565701 [PubMed]

PMCID: PMC6764777


EC Neurology
Differences in Rate of Cognitive Decline and Caregiver Burden between Alzheimer's Disease and Vascular Dementia: a Retrospective Study.

PMID: 27747317 [PubMed]

PMCID: PMC5065347


EC Pharmacology and Toxicology
Will Blockchain Technology Transform Healthcare and Biomedical Sciences?

PMID: 31460519 [PubMed]

PMCID: PMC6711478


EC Pharmacology and Toxicology
Is it a Prime Time for AI-powered Virtual Drug Screening?

PMID: 30215059 [PubMed]

PMCID: PMC6133253


EC Psychology and Psychiatry
Analysis of Evidence for the Combination of Pro-dopamine Regulator (KB220PAM) and Naltrexone to Prevent Opioid Use Disorder Relapse.

PMID: 30417173 [PubMed]

PMCID: PMC6226033


EC Anaesthesia
Arrest Under Anesthesia - What was the Culprit? A Case Report.

PMID: 30264037 [PubMed]

PMCID: PMC6155992


EC Orthopaedics
Distraction Implantation. A New Technique in Total Joint Arthroplasty and Direct Skeletal Attachment.

PMID: 30198026 [PubMed]

PMCID: PMC6124505


EC Pulmonology and Respiratory Medicine
Prevalence and factors associated with self-reported chronic obstructive pulmonary disease among adults aged 40-79: the National Health and Nutrition Examination Survey (NHANES) 2007-2012.

PMID: 30294723 [PubMed]

PMCID: PMC6169793


EC Dental Science
Important Dental Fiber-Reinforced Composite Molding Compound Breakthroughs

PMID: 29285526 [PubMed]

PMCID: PMC5743211


EC Microbiology
Prevalence of Intestinal Parasites Among HIV Infected and HIV Uninfected Patients Treated at the 1o De Maio Health Centre in Maputo, Mozambique

PMID: 29911204 [PubMed]

PMCID: PMC5999047


EC Microbiology
Macrophages and the Viral Dissemination Super Highway

PMID: 26949751 [PubMed]

PMCID: PMC4774560


EC Microbiology
The Microbiome, Antibiotics, and Health of the Pediatric Population.

PMID: 27390782 [PubMed]

PMCID: PMC4933318


EC Microbiology
Reactive Oxygen Species in HIV Infection

PMID: 28580453 [PubMed]

PMCID: PMC5450819


EC Microbiology
A Review of the CD4 T Cell Contribution to Lung Infection, Inflammation and Repair with a Focus on Wheeze and Asthma in the Pediatric Population

PMID: 26280024 [PubMed]

PMCID: PMC4533840


EC Neurology
Identifying Key Symptoms Differentiating Myalgic Encephalomyelitis and Chronic Fatigue Syndrome from Multiple Sclerosis

PMID: 28066845 [PubMed]

PMCID: PMC5214344


EC Pharmacology and Toxicology
Paradigm Shift is the Normal State of Pharmacology

PMID: 28936490 [PubMed]

PMCID: PMC5604476


EC Neurology
Examining those Meeting IOM Criteria Versus IOM Plus Fibromyalgia

PMID: 28713879 [PubMed]

PMCID: PMC5510658


EC Neurology
Unilateral Frontosphenoid Craniosynostosis: Case Report and a Review of the Literature

PMID: 28133641 [PubMed]

PMCID: PMC5267489


EC Ophthalmology
OCT-Angiography for Non-Invasive Monitoring of Neuronal and Vascular Structure in Mouse Retina: Implication for Characterization of Retinal Neurovascular Coupling

PMID: 29333536 [PubMed]

PMCID: PMC5766278


EC Neurology
Longer Duration of Downslope Treadmill Walking Induces Depression of H-Reflexes Measured during Standing and Walking.

PMID: 31032493 [PubMed]

PMCID: PMC6483108


EC Microbiology
Onchocerciasis in Mozambique: An Unknown Condition for Health Professionals.

PMID: 30957099 [PubMed]

PMCID: PMC6448571


EC Nutrition
Food Insecurity among Households with and without Podoconiosis in East and West Gojjam, Ethiopia.

PMID: 30101228 [PubMed]

PMCID: PMC6086333


EC Ophthalmology
REVIEW. +2 to +3 D. Reading Glasses to Prevent Myopia.

PMID: 31080964 [PubMed]

PMCID: PMC6508883


EC Gynaecology
Biomechanical Mapping of the Female Pelvic Floor: Uterine Prolapse Versus Normal Conditions.

PMID: 31093608 [PubMed]

PMCID: PMC6513001


EC Dental Science
Fiber-Reinforced Composites: A Breakthrough in Practical Clinical Applications with Advanced Wear Resistance for Dental Materials.

PMID: 31552397 [PubMed]

PMCID: PMC6758937


EC Microbiology
Neurocysticercosis in Child Bearing Women: An Overlooked Condition in Mozambique and a Potentially Missed Diagnosis in Women Presenting with Eclampsia.

PMID: 31681909 [PubMed]

PMCID: PMC6824723


EC Microbiology
Molecular Detection of Leptospira spp. in Rodents Trapped in the Mozambique Island City, Nampula Province, Mozambique.

PMID: 31681910 [PubMed]

PMCID: PMC6824726


EC Neurology
Endoplasmic Reticulum-Mitochondrial Cross-Talk in Neurodegenerative and Eye Diseases.

PMID: 31528859 [PubMed]

PMCID: PMC6746603


EC Psychology and Psychiatry
Can Chronic Consumption of Caffeine by Increasing D2/D3 Receptors Offer Benefit to Carriers of the DRD2 A1 Allele in Cocaine Abuse?

PMID: 31276119 [PubMed]

PMCID: PMC6604646


EC Anaesthesia
Real Time Locating Systems and sustainability of Perioperative Efficiency of Anesthesiologists.

PMID: 31406965 [PubMed]

PMCID: PMC6690616


EC Pharmacology and Toxicology
A Pilot STEM Curriculum Designed to Teach High School Students Concepts in Biochemical Engineering and Pharmacology.

PMID: 31517314 [PubMed]

PMCID: PMC6741290


EC Pharmacology and Toxicology
Toxic Mechanisms Underlying Motor Activity Changes Induced by a Mixture of Lead, Arsenic and Manganese.

PMID: 31633124 [PubMed]

PMCID: PMC6800226


EC Neurology
Research Volunteers' Attitudes Toward Chronic Fatigue Syndrome and Myalgic Encephalomyelitis.

PMID: 29662969 [PubMed]

PMCID: PMC5898812


EC Pharmacology and Toxicology
Hyperbaric Oxygen Therapy for Alzheimer's Disease.

PMID: 30215058 [PubMed]

PMCID: PMC6133268


News and Events


November Issue Release

We always feel pleasure to share our updates with you all. Here, notifying you that we have successfully released the November issue of respective journals and the latest articles can be viewed on the current issue pages.

Submission Deadline for Upcoming Issue

ECronicon delightfully welcomes all the authors around the globe for effective collaboration with an article submission for the upcoming issue of respective journals. Submissions are accepted on/before December 14, 2022.

Certificate of Publication

ECronicon honors with a "Publication Certificate" to the corresponding author by including the names of co-authors as a token of appreciation for publishing the work with our respective journals.

Best Article of the Issue

Editors of respective journals will always be very much interested in electing one Best Article after each issue release. The authors of the selected article will be honored with a "Best Article of the Issue" certificate.

Certifying for Review

ECronicon certifies the Editors for their first review done towards the assigned article of the respective journals.

Latest Articles

The latest articles will be updated immediately on the articles in press page of the respective journals.