Research Article
Volume 1 Issue 2 - 2015
Comparative Analysis of Screw Loosening in Titanium and Zirconia Abutments-An In vitro Study
Rafaella Monteiro Oliveira Cid1,3*, Gustavo Jose Giardini Lahr2, Kyle Stanley1,3, Adriano Almeida Goncalves Siqueira 2 and Antonio Carlos Cardoso1
1Department of Dentistry, Federal University of Santa Catarina, Brazil
2Department of Mechanical Engineering, University of São Paulo, Brazil
33Division of Restorative Sciences, Ostrow School of Dentistry of USC, USA
*Corresponding Author: Rafaella Monteiro Oliveira Cid, Department of Dentistry, Federal University of Santa Catarina, Health Sciences Center, Florianopolis, Santa Catarina, Brazil.
Received: January 29, 2015; Published: February 19, 2015
Citation: Rafaella Monteiro Oliveira Cid., et al. “Comparative Analysis of Screw Loosening in Titanium and Zirconia Abutments-An In vitro Study”. EC Dental Science 1.2 (2015): 83-89.
Abstract
Background: Compare of the screw loosening in two different implant-supported abutments (titanium and zirconia) and the influence of repeated application of torque on the fixation screw.
Methods: The torque of the titanium screw loosening was analyzed with two different implant-supported abutments: Titanium (n = 10) and Zirconia (n = 10). These screws/abutments were fixed for the test using external hex implants. A low-load robot (KUKA KR-16 2) with a high precision torque sensor (Industrial Automation Technologies) and a square key were used to measure force of the reverse torque. Each screw/abutment was repeatedly tightened (TR1-TR10) on the implants with a torque of 30 Ncm. The reverse torque values were recorded in a database using Kuka System Software V5.X. The Mann - Whitney and the Wilcoxon test were also performed.
Results: A statistically significant difference was not found only in the sample 3 (p = 0.05) in the comparative analysis between both materials (Ti and Zr). The mean reverse torque applied to loss the preload was 26.3 Ncm for Ti and 22.6 Ncm for Zr. The difference between the initial reverse torque (TR1) and final (TR10) was determined TR1 had an average of 24.8 Ncm (Ti) and 20.8 Ncm (Zr); TR 10 had an average of 27.4 Ncm (Ti) and 23.9 Ncm (Zr).
Conclusion: The titanium abutment showed higher resistance to the loosening of the titanium screw compared to the zirconia abutment. The first preload applied tended to loosen more easily than the last torque applied in the same screw.
Keywords: Zirconia; Titanium; Torque; External hex implants
Introduction
Screw loosening is the most common problem in implant-supported prostheses, which causes discomfort and insecurity among patients. Once the screws have loosened, they may break or lead to a fracture of other elements of the prosthesis. Loosening of screws and consequently, of the prosthesis may irritates soft tissue, causes inflammation and often pain [1-3].
Customizable metal or ceramic abutments are positioned directly above the implants [4-6]. Metal abutments such as titanium alloys offer excellent stability and are resistant to distortion. Results from clinical studies have shown excellent survival rates for this type of abutment in supported restorations [7]. The disadvantage is the dark-grey color that can reflect a grayish coloration in the peri-implant mucosa, thus negatively affecting the esthetic outcome [8].
Currently, it is possible to obtain ceramic abutments from ceramics reinforced with alumina or zirconia [9]. These ceramic abutments have esthetic benefits due to their color [10], as well as a lower bacterial adhesion [11]. The disadvantage of ceramic abutments include a lower resistance to tension forces, and micro-structural defects of the material, which may cause fissures and result in fractures [12].
Loosening of fixation screws occurs more commonly in the first year and decreases in subsequent years. This phenomenon can be explained by the period of adaptation after the initial delivery of the prosthesis [13].
The abutment and the implant form a rigid union. The preload generated in the screw aims to promote a clamping force and compression between the assembly of the implant (abutment/implant). Thus, the preload seems to be proportional to the fixation force [3]. This compression offers resistance to external shear loads and improves resistance to fatigue in the abutment/implant ensemble [14].
The looseness of the fixation joint and the seating of the ensemble also depend on the presence of irregular points on the surface contact, the solidity of the implant surface, optimal fixation between screw and the abutment, as well as the load applied to the system as a whole. When there is a relaxation of the clamping, tightening torque is applied in order to recover the preload [2].
This study was conceived because of a question related to the different mechanical performances of titanium and zirconia abutments on external hex implants. The aim of the present study was to analyze screw loosening in two different implant-supported abutments (Ti and Zr) and the influence of repeated application of torque on the fixation screw, while observing the amount of reverse torque required to the loosen of the preload.
The null-hypothesis considered was that the screw loosening would be different between the two different prosthetic implant-supported abutments and that repeated application of torque on the fixation screw would have an influence on the value of the loosening of the preload.
Materials and Methods
The present study was lead in the Laboratory of Mechatronics, Department of Mechanical Engineering, University of São Paulo (USP; Sao Carlos, SP, Brazil). Twenty titanium screws with a square key size of 1.27 mm (Conexao Sistema de Protese; Sao Paulo, SP, Brazil) and twenty abutments (n = 10 Ti; n = 10 Zr) were analyzed. The abutments were divided into two groups: Group 1: pre-fabricated titanium abutments (Conexao Sistemas de Protese; Sao Paulo, SP, Brazil) and Group 2: zirconia CAD/CAM abutments.
The abutments with the respective screws were fixed for testing using an external hex implant (Ø 3.75 x 11.5 mm, Conexao Sistemas de Protese; Sao Paulo, SP, Brazil). The implants were embeded perpendicular to the horizontal plane in auto polymerizing acrylic resin (Duralay; Reliance Dental MFG Company, Illinois, United States) in a standardized manner, using a delineator together with an adapted device.
A low-load robot (KUKA KR-16 2 KUKA Roboter of Brazil Ltda; Sao Paulo, Brazil) was used to apply the torque. A torque sensor together with the square key (Conexao Sistema de Protese; Sao Paulo, SP, Brazil) was attached to the robots extremities to measure the torque and reverse torque of the fixation screws. The sensor is composed of a transducer, a highly flexible protected cable and an intelligent data acquisition system.
Figure 1: Robot (KUKA KR-16 2) with a torque sensor and the square key were attached to apply torques and reverse torques.
Each fixation screw and the respective abutment (Ti and Zr) were tightened repeatedly on the implants by a specifically created program. Initial torque of 30 Ncm; waiting five minutes (time required for an initial elastic and plastic deformation of the material) and a new torque of 30 Ncm was performed, waiting five minutes again. After that a reverse torque was applied, and the abutments were removed. Ten cycles of insertion/removal were performed with each abutment. The torque and reverse torque values were recorded in a database using Kuka System Software V5.X. (KUKA Roboter of Brazil Ltda; Sao Paulo, SP, Brazil).
Descriptive analysis was performed with the data, exhibiting central tendency measures (mean and median) of reverse torque according to the different materials (Ti and Zr). The Mann - Whitney non-parametric statistical test was performed to determine the difference in the reverse torque values.
In order to test the difference between the initial and final reverse torque values, the Wilcoxon non-parametric test was conducted [15]. The groups were considered to be significantly different when the p-value was less than 0.05.
Results
The central tendency measures (mean and median) of the reverse torque according to the different materials (Ti and Zr) are presented in the Table 1.
A statistically significant difference was not found only in the sample 3 (p = 0.05) in the comparative analysis between materials. The mean reverse torque applied to loss of preload was 26.3 Ncm for titanium and 22.6 Ncm for zirconia abutments.
The mean and median difference between the initial reverse torque (TR1) and the final (TR10) were to: TR1 Titanium 24.8 Ncm and 25.8 Ncm; And to the Zirconia 20.8 Ncm and 21.7 Ncm. TR10 had for Ti 27.4 Ncm and 28.1 Ncm, and for Zr 23.9 Ncm and 23.4 Ncm respectively. The first torque applied to the samples tends to loose more easily the preload when compared to the last torque (Figure 2).
  Titanium Zirconia Value*
Reverse Torque Median Mean (SD) Median Mean (SD)  
Sample 1 25,80 24,81 (-5,70) 21,78 20,88 (-6,12) 0,03
Sample 2 25,50 26,04 (-2,88) 22,32 21,15 (-6,45) 0,02
Sample 3 27,30 24,45 (-7,98) 22,86 22,86 (-3,75) 0,05
Sample 4 27,96 27,45 (-2,85) 23,76 23,37 (-3,60) 0,01
Sample 5 26,97 25,44 (-5,16) 22,17 22,20 (-3,60) 0,04
Sample 6 27,54 26,34 (-3,84) 22,77 22,56 (-3,72) 0,01
Sample 7 28,68 26,37 (-5,61) 22,77 23,10 (-4,32) 0,04
Sample 8 28,86 27,84 (-2,82) 23,34 23,07 (-3,54) 0,00
Sample 9 29,31 26,85 (-5,85) 24,33 23,43 (-3,84) 0,01
Sample 10 28,14 27,45 (-3,57) 23,43 23,94 (-4,14) 0,04
Table 1: Measures of central tendency and dispersion of successive removable torques according to the type of the material.
* Test of Mann-Whitne.
Figure 2: Box-plot of the first and the last reverse torque comparing the material type.
* Wilcoxon.
Discussion
The present study evaluated the screw loosening in two different implant-supported abutments and the influence of repeated application of torque on the fixation screw, observing th amount of reverse torque required to loosen of the titanium screws. The null-hypothesis considered is that the screw loosening would be different between the two abutments and that repeated application of torque on the fixation screw would have an influence on the value of the loosening of the preload.
Implant supported prosthesis have already been successfully established. However, they often present mechanical and biological problems. One of the mechanical problems, typified in the present study, is the screw loosening [1,2]. And the most frequently mainly loosening occurs during the first two years after the rehabilitation on the traditional external hex implants [1,16].
The stability of the external connection of the abutments/implant and the implant was improved by changing the alloys of screws and applying adequate torque values to establish a greater preload [17]. Therefore, external hex implants exhibit the least favorable mechanical performance and the highest percentage of screw loosening in abutments. Also, this type of implant still with a high range of use in the global market.
The screws alloy routinely used in clinics are made of titanium with a torque applied at 30 Ncm for both titanium and zirconia abutments. According to McGlumphy et al. [18], when a screw unites two parts, loosening of the screw can only occur when the external forces applied are greater than the internal forces (tightening torque).
Haack et al. [19] stated that the preload maintains the threads of the screw in close contact with the threads of the implant, generating a force of union between the head of the screw and the abutment fitting surface, and from the abutment fitting surface to the platform of the implant. A reduction in the preload values is expected in the first seconds or minutes after the application of the torque, due to the deformation of the fitting contact surfaces between the assembly. Therefore, many authors recommend a second torque with the same value of the initial torque applied [16].
The phenomenon called sedimentation is based on the fact that any surface is completely flat and that all machined surfaces exhibit some degree of roughness. Therefore, when a fixation screw is screwed into an implant for the first time, there is a slight adjustment between the irregularities of the fitting surfaces, which we can understand as screw adaptation or seating. It is estimated that the mean preload values are reduced between 2% and 10% after the plastic deformation of these irregularities [2,14]. The screw will loosen more easily in the first preload due to plastic deformation and greater settlement of the material [13,20].
In 1991, Jemt [14] assessed 391 prostheses in edentulous jaws and mandibles and found that 120 (30.6%) of them exhibited loose screws two weeks after insertion. Three months later, the 120 prostheses that had required retightening of the screws exhibited 94% stability.
However, a number of factors may affect the stability of screws and probably will cause the loosening due to the tension. These factors are as follows: 1) geometric design and precision of the adaptation in the union of the components; 2) passive adaptation of the abutment to the implant; 3) difference in the coefficient of friction of screws which in turn, depends on the toughness of the thread material and the finishing of surfaces; 4) the shape of the screws; 5) the torque application system used and the quality control of the manufacturer, among others [21,22].
Currently, personalized abutments can be fabricated from different metal or ceramic materials. Metal alloys, such as titanium, offer stability and produce clinical results with excellent longevity rates [23]. The disadvantage is a grayish coloration, which may, in some cases, reflect in the peri-implant mucosa, with a negative esthetic effect [8].
Ceramic abutments can be used as an alternative in situations that, above all, require an esthetic result. The defect of ceramic material is the weakness: it exhibits less resistance to tensile forces as well as a number of micro-structural defects. However, reconstructions with zirconia structures have recorded clinical successes [24].
In a clinical study randomly controlled test (RCT) using zirconia and titanium abutments on posterior crowns, a survival rate of 100% was recorded for ceramic abutments after three years [25]. Curiously, loosening of fixation screws was one of the few technical complications that occurred with zirconia abutments [24].
Zirconia abutments have esthetic advantages but, even when designed by a CAD/CAM system to improve the adaptation to the implant platform, they usually exhibit lower reverse torque levels than titanium abutments. This result may be a consequence of the greater rotational mismatch of the components, even those obtained by a CAD/CAM system, in comparison to abutments with a metallic base [19]. Furthermore, according to Binon [5], ceramic abutments cannot be machined to the same degree of precision as metal abutments.
A systematic review displayed that there were no statistically significant differences in the general performance of ceramic and metal abutments. Ceramic abutments exhibit similar survival rates and complications to metallic abutments [25]. The present study found that zirconia abutments are more frequently associated with loosening of fixation screws, due to the availability of a lower preload after application, in comparison with titanium abutments.
Conclusion
Our research concluded thattitanium abutments showed high resistance to screw loosening when compared to the zirconia abutments, suggesting that the type of material comprising on a implant prosthetic will influence the amount of torque required to cause screw loosening. The first preload applied to the screw tends to loosen more easily than the last torque applied in the same screw.
Conflict of Interest
None of the authors had any financial or personal conflict of interest with regard to this study.
Acknowledgments
The Conexao Sistemas de Protese and JC Estetica Dentaria supported this work. We thank for their assistance.
Bibliography
  1. Weiss EI., et al. “Effect of repeated closures on opening torque values in seven abutment-implant systems”. The Journal of Prosthetic Dentistry 84.2 (2000): 194-199.
  2. Jorneus L., et al. “Loads and designs of screw joints for single crowns supported by osseointegrated implants”. The International Journal of Oral and Maxillofacial Implants 7.3 (1992): 353-359.
  3. Versluis A., et al. “Numerical analysis of a dental implant system preloaded with a washer”. The International Journal of Oral and Maxillofacial Implants 14.3 (1999): 337-341.
  4. Lewis SG., et al. “The UCLA abutment: a four-year review”. The Journal of Prosthetic Dentistry 67.4 (1992): 509-515.
  5. Binon PP. “Implants and components: entering the new millennium”. The International Journal of Oral and Maxillofacial Implants 15.1 (2000): 76-91.
  6. Taylor TD and Agar JR. “Twenty years of progress in implant prosthodontics”. The Journal of Prosthetic Dentistry 88.1 (2002): 89-95.
  7. Andersson B., et al. “Alumina ceramic implant abutments used for single-tooth replacement: a prospective 1 to 3 year multicenter study”. International Journal of Prosthodontics14.5 (2001): 432-438.
  8. Jung RE., et al. “In vitro color changes of the covering mucosa caused by restorative materials”. The International Journal of Periodontics and Restorative Dentistry 27.3 (2007): 251-257.
  9. Garine WN., et al. “Measurement of the rotational misfit and implant-abutment gap of allceramic abutments”. The International Journal of Oral and Maxillofacial Implants 22.6 (2007): 928-938.
  10. Jung RE., et al. “A systematic review of the 5-year survival and complication rates of implant-supported single crowns”. Clinical Oral Implants Research19.2 (2008): 119-130.
  11. Scarano A., et al. “Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study”. Journal of Periodontology75.2 (2004): 292-296.
  12. Belser UC., et al. “Outcome analysis of implant restorations located in the anterior maxilla: A review of the recent literature”. The International Journal of Oral and Maxillofacial Implants 19.Suppl (2004): 30-42.
  13. Lee J., et al. “Wave analysis of implant screw loosening using an air cylindrical cyclic loading device”. The Journal of Prosthetic Dentistry 88.4 (2002): 402-408.
  14. Jemt T. “Failures and complications in 391 consecutively inserted fixed prostheses supported by Bränemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup”. The International Journal of Oral and Maxillofacial Implants 6.3 (1991): 270-276.
  15. Kirkwood BR and Sterne JAC. “Medical statistics”. Massachusetts: Blackwell, 2003.
  16. Merz BR., et al. “Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection”. The International Journal of Oral and Maxillofacial Implants 15.4 (2000): 519-526.
  17. Siamos G., et al. “Relationship between implant preload and screw loosening on implant-supported prostheses”. The Journal of Oral Implantology 28.2 (2002): 67-73.
  18. McGlumphy EA., et al. “Implant screw mechanics”. Dental Clinics of North America 42.1 (1998): 71-89.
  19. Haack JE., et al. “Elongation and preload stress in dental implant abutment screws”. International Journal of Oral & Maxillofacial Implants 10.5 (1995): 529-536.
  20. Shigley JE. et al. “Mechanical engineering design”. 3rd ed. New York: McGraw Hill (1977): 240-245.
  21. Burguete RL., et al. “Tightening characteristics for screwed joints in osseointegrated dental implants”. Journal of Prosthetic Dentistry 71.6 (1994): 592-599.
  22. Tan KB and Nicholls JI. “Implant-abutment screw joint preload of 7 hex-top abutment systems”. International Journal of Oral & Maxillofacial Implants 16.3 (2001): 367-377.
  23. Andersson B., et al. “Single-tooth restorations supported by osseointegrated implants: results and experiences from a prospective study after 2 to 3 years”. International Journal of Oral & Maxillofacial Implants 10.6 (1995): 702-711.
  24. Glauser R., et al. “Experimental zirconia abutments for implant-supported singletooth restorations in esthetically demanding regions: 4-year results of a clinical study”. International Journal of Prosthodontics 17.3 (2004): 285-290.
  25. Zembic A., et al. “Randomized controlled clinical Trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results”. Clinical Oral Implants Research 20.8 (2009): 802-808.
Copyright: © 2015 Rafaella Monteiro Oliveira Cid., et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

PubMed Indexed Article


EC Pharmacology and Toxicology
LC-UV-MS and MS/MS Characterize Glutathione Reactivity with Different Isomers (2,2' and 2,4' vs. 4,4') of Methylene Diphenyl-Diisocyanate.

PMID: 31143884 [PubMed]

PMCID: PMC6536005


EC Pharmacology and Toxicology
Alzheimer's Pathogenesis, Metal-Mediated Redox Stress, and Potential Nanotheranostics.

PMID: 31565701 [PubMed]

PMCID: PMC6764777


EC Neurology
Differences in Rate of Cognitive Decline and Caregiver Burden between Alzheimer's Disease and Vascular Dementia: a Retrospective Study.

PMID: 27747317 [PubMed]

PMCID: PMC5065347


EC Pharmacology and Toxicology
Will Blockchain Technology Transform Healthcare and Biomedical Sciences?

PMID: 31460519 [PubMed]

PMCID: PMC6711478


EC Pharmacology and Toxicology
Is it a Prime Time for AI-powered Virtual Drug Screening?

PMID: 30215059 [PubMed]

PMCID: PMC6133253


EC Psychology and Psychiatry
Analysis of Evidence for the Combination of Pro-dopamine Regulator (KB220PAM) and Naltrexone to Prevent Opioid Use Disorder Relapse.

PMID: 30417173 [PubMed]

PMCID: PMC6226033


EC Anaesthesia
Arrest Under Anesthesia - What was the Culprit? A Case Report.

PMID: 30264037 [PubMed]

PMCID: PMC6155992


EC Orthopaedics
Distraction Implantation. A New Technique in Total Joint Arthroplasty and Direct Skeletal Attachment.

PMID: 30198026 [PubMed]

PMCID: PMC6124505


EC Pulmonology and Respiratory Medicine
Prevalence and factors associated with self-reported chronic obstructive pulmonary disease among adults aged 40-79: the National Health and Nutrition Examination Survey (NHANES) 2007-2012.

PMID: 30294723 [PubMed]

PMCID: PMC6169793


EC Dental Science
Important Dental Fiber-Reinforced Composite Molding Compound Breakthroughs

PMID: 29285526 [PubMed]

PMCID: PMC5743211


EC Microbiology
Prevalence of Intestinal Parasites Among HIV Infected and HIV Uninfected Patients Treated at the 1o De Maio Health Centre in Maputo, Mozambique

PMID: 29911204 [PubMed]

PMCID: PMC5999047


EC Microbiology
Macrophages and the Viral Dissemination Super Highway

PMID: 26949751 [PubMed]

PMCID: PMC4774560


EC Microbiology
The Microbiome, Antibiotics, and Health of the Pediatric Population.

PMID: 27390782 [PubMed]

PMCID: PMC4933318


EC Microbiology
Reactive Oxygen Species in HIV Infection

PMID: 28580453 [PubMed]

PMCID: PMC5450819


EC Microbiology
A Review of the CD4 T Cell Contribution to Lung Infection, Inflammation and Repair with a Focus on Wheeze and Asthma in the Pediatric Population

PMID: 26280024 [PubMed]

PMCID: PMC4533840


EC Neurology
Identifying Key Symptoms Differentiating Myalgic Encephalomyelitis and Chronic Fatigue Syndrome from Multiple Sclerosis

PMID: 28066845 [PubMed]

PMCID: PMC5214344


EC Pharmacology and Toxicology
Paradigm Shift is the Normal State of Pharmacology

PMID: 28936490 [PubMed]

PMCID: PMC5604476


EC Neurology
Examining those Meeting IOM Criteria Versus IOM Plus Fibromyalgia

PMID: 28713879 [PubMed]

PMCID: PMC5510658


EC Neurology
Unilateral Frontosphenoid Craniosynostosis: Case Report and a Review of the Literature

PMID: 28133641 [PubMed]

PMCID: PMC5267489


EC Ophthalmology
OCT-Angiography for Non-Invasive Monitoring of Neuronal and Vascular Structure in Mouse Retina: Implication for Characterization of Retinal Neurovascular Coupling

PMID: 29333536 [PubMed]

PMCID: PMC5766278


EC Neurology
Longer Duration of Downslope Treadmill Walking Induces Depression of H-Reflexes Measured during Standing and Walking.

PMID: 31032493 [PubMed]

PMCID: PMC6483108


EC Microbiology
Onchocerciasis in Mozambique: An Unknown Condition for Health Professionals.

PMID: 30957099 [PubMed]

PMCID: PMC6448571


EC Nutrition
Food Insecurity among Households with and without Podoconiosis in East and West Gojjam, Ethiopia.

PMID: 30101228 [PubMed]

PMCID: PMC6086333


EC Ophthalmology
REVIEW. +2 to +3 D. Reading Glasses to Prevent Myopia.

PMID: 31080964 [PubMed]

PMCID: PMC6508883


EC Gynaecology
Biomechanical Mapping of the Female Pelvic Floor: Uterine Prolapse Versus Normal Conditions.

PMID: 31093608 [PubMed]

PMCID: PMC6513001


EC Dental Science
Fiber-Reinforced Composites: A Breakthrough in Practical Clinical Applications with Advanced Wear Resistance for Dental Materials.

PMID: 31552397 [PubMed]

PMCID: PMC6758937


EC Microbiology
Neurocysticercosis in Child Bearing Women: An Overlooked Condition in Mozambique and a Potentially Missed Diagnosis in Women Presenting with Eclampsia.

PMID: 31681909 [PubMed]

PMCID: PMC6824723


EC Microbiology
Molecular Detection of Leptospira spp. in Rodents Trapped in the Mozambique Island City, Nampula Province, Mozambique.

PMID: 31681910 [PubMed]

PMCID: PMC6824726


EC Neurology
Endoplasmic Reticulum-Mitochondrial Cross-Talk in Neurodegenerative and Eye Diseases.

PMID: 31528859 [PubMed]

PMCID: PMC6746603


EC Psychology and Psychiatry
Can Chronic Consumption of Caffeine by Increasing D2/D3 Receptors Offer Benefit to Carriers of the DRD2 A1 Allele in Cocaine Abuse?

PMID: 31276119 [PubMed]

PMCID: PMC6604646


EC Anaesthesia
Real Time Locating Systems and sustainability of Perioperative Efficiency of Anesthesiologists.

PMID: 31406965 [PubMed]

PMCID: PMC6690616


EC Pharmacology and Toxicology
A Pilot STEM Curriculum Designed to Teach High School Students Concepts in Biochemical Engineering and Pharmacology.

PMID: 31517314 [PubMed]

PMCID: PMC6741290


EC Pharmacology and Toxicology
Toxic Mechanisms Underlying Motor Activity Changes Induced by a Mixture of Lead, Arsenic and Manganese.

PMID: 31633124 [PubMed]

PMCID: PMC6800226


EC Neurology
Research Volunteers' Attitudes Toward Chronic Fatigue Syndrome and Myalgic Encephalomyelitis.

PMID: 29662969 [PubMed]

PMCID: PMC5898812


EC Pharmacology and Toxicology
Hyperbaric Oxygen Therapy for Alzheimer's Disease.

PMID: 30215058 [PubMed]

PMCID: PMC6133268


News and Events


March Issue Release

We always feel pleasure to share our updates with you all. Here, notifying you that we have successfully released the March issue of respective journals and the latest articles can be viewed on the current issue pages.

Submission Deadline for Upcoming Issue

ECronicon delightfully welcomes all the authors around the globe for effective collaboration with an article submission for the upcoming issue of respective journals. Submissions are accepted on/before April 03, 2023.

Certificate of Publication

ECronicon honors with a "Publication Certificate" to the corresponding author by including the names of co-authors as a token of appreciation for publishing the work with our respective journals.

Best Article of the Issue

Editors of respective journals will always be very much interested in electing one Best Article after each issue release. The authors of the selected article will be honored with a "Best Article of the Issue" certificate.

Certifying for Review

ECronicon certifies the Editors for their first review done towards the assigned article of the respective journals.

Latest Articles

The latest articles will be updated immediately on the articles in press page of the respective journals.